DETAILED NOTES ON DP50RB

Detailed Notes on Dp50rb

Detailed Notes on Dp50rb

Blog Article

1.2.two Warning Labels Warning Labels Meaning Please carefully read through this manual right before use device. The subsequent labels really are a. Will not spot the product over a sloped area. Or else the obtainable in the event the process system may slide, causing individual injuries or the machine will work with the cell malfunction.

Maximum four situations tasking for 1 transmitted beam, resulting in outstanding time resolution and higher body rate.

Get a whole and prolonged look at from the anatomical composition by way of panoramic imaging coupled with velocity indication and forward/backward scan skill making scanning a lot easier, smoother and more controllable.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

By continuing your pay a visit to on our Site, you might be consenting to our use of cookies. Having said that, you could transform your cookie settings at any time.  Cookie desire Take and Continue

Any time you cease the scanning as well as the graphic capture, you should ability off the procedure and disconnect the technique from the AC energy source, then pull out AC electric power cables. Site 109: Battery Connecting Board

S. must offer the Division using an e mail tackle if they have got one. The emails provided could possibly be employed for Formal communication Using the licensee. On the other hand e mail addresses are general public record. If you don't wish to provide a private deal with, be sure to give the Department with the email handle which can be produced accessible to the general public. Remember to see our Chapter 455 page to find out If you're affected by this variation.

Explore better diagnostic information by extended check out from the anatomical composition on all convex probes.

iZoom™ enables correct viewing of picture from distance iWorks™ Protocol will help standardize workflow and cut down Test situations

five.2.3 Geometric positioning accuracy Longitudinal geometric positioning precision  Check Action: Do adjustments as the way in which in screening the utmost depth. File the space by 20mm Each and every phase to the longitudinal targets line utilizing the measurement caliper; Decide on the value with the greatest error (to 20mm), determine the precision using the formula below The measurement caliper really should be positioned for the higher edge of the target, NOTE:... Web site seventy nine Transverse geometric positioning accuracy  Check Move: Cover the scan surface with the phantom with water or few gel, Carefully Get in touch with the probe Together with the scan surface area Adjust the depth, producing the transverse targets to generally be shown within the image. Adjust the main target issue to generally be posited beside the transverse targets (the typical will not be crystal clear) Change parameters like achieve, TGC, producing Every single transverse targets to get clearly exhibited. Site 80 five.five.2.4 Blackout Region Exam Action: Include the scan surface of the phantom with drinking water or pair gel, gently contact the probe Along with the scan surface area Modify the depth at a decreased value, and established the main focus at the nearest spot to the scan floor. Minimize the worth of parameters like AP, Obtain until the track record sound just is often witnessed. Web page eighty one: Computer software Update And Routine maintenance

Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.

Be aware: Ahead of uploading the log, be sure the ultrasound program has been connected to network, normally, the program might warn “could not connect with server” The server (smtp.

Efficiency Take a look at 5.five.one Take a look at Process Resolution Detection depth Geometric Place Accuracy Blackout region check File the Examination photographs 5.five.two Examination Information The impression applied here is just for reference, stick to the graphic outcome in the true Notice: circumstance. Needs: Screen: set the distinction and brightness on the clinical software worth (or the default status) Procedure surroundings: dim place, simulating the clinical software atmosphere. Web page seventy six In problem which the transverse resolution testing targets are horizontally exhibited, document the minimum length of two targets which can be Evidently acknowledged. Repeat the Procedure over for the transverse resolution screening targets at other depths. As revealed in figure underneath. Axial resolution ... Webpage seventy seven When utilizing the convex probe, maintain the transverse resolution screening targets to NOTE: be shown close to the midline. When employing a linear probe with steer function, will not activate the steer functionality when carry out the transverse resolution examination. Zoom inside the region wherever the targets Found if Dp50rb necessary. The diameter in the goal place at a particular depth is equal on the transverse resolution within the depth. Page seventy eight five.

Following replacing the CPU module, critical file has to be created Again in accordance with the new MAC address and prepared into HDD with the device. Or else, the configuration operate with the products will likely be dropped. Immediately after eradicating the CPU module, Take out panhead screws with washers (twelve M3X6) preset on the main device box, you usually takes from the board. Site 118 Figure eight-29 Disassemble the User interface Assembly (1) Hold the higher edge of control panel assembly, and open up up the control panel. Figure eight-30 Disassemble the User interface Assembly (two) Soon after eliminating a single countersunk head self-tapping screw PT3X10 set around the user interface and acquire out the plug on the keyboard and the key device connecting cables, you could possibly clear away the control panel assembly.

A wise new shape, Increased mobility and convenient Procedure make DP-50 like minded for all clinical configurations.

Report this page